CS90 90mm Optical Shutter

CS90 90mm Optical Shutter

Part Number: CS90HS1T0

Option 

-Driver Compatibility

-Housing

-Blade Option

-Electronic Sync.

-Connector

-For use in Vacuum

-Mount

Key Features

-Large 90mm aperture

-Uni-stable operation

-6-bladed design

-Slim form-factor

-RoHS Compliant

-Transfer time on opening: 46.0 milliseconds

-Total opening time: 66.0 milliseconds

-Configured for the VCM-D1 Shutter Driver

 

문의하기

→ 상품 상세 정보 : CS90 90mm Optical Shutter

Overview


The Uniblitz CS90 has been designed to provide accurate, repeatable exposures for a wide variety of applications such as telescopy and aerospace. The slim form-factor provides a very large 90mm aperture that can be inserted into a 7.00 inch diameter housing. The CS90 is available in a housed or an un-housed configuration for OEM applications (or simply where spatial limitations are a consideration).

Uni-stable shutter devices, like the CS90, require power to hold the blades in the open state.

A normally open configuration of this device is available by special order. Please contact us for more information.

Specifications


For additional technical information please see the CS90 Optical Shutter Datasheet.


Actuator Coil Resistance Pulse Voltage to Open Hold Voltage 1(Nominal)
Primary 24 OHMS +70 VDC +7 VDC / +5 VDC 2
Secondary 3 24 OHMS +70 VDC +7 VDC / +5 VDC 2

 

Weight Unhoused Weight Housed Operating Temp. Max. Opening Bounce Max. Closing Bounce Max. Freq. of Operation 4 Number of Shutter Blades
11.40 oz
(0.32 kg)
24.10 oz (0.68 kg) 0 – 80 °C 15% 5% 1.0 Hz / 3.0 Hz 6

 

1 Voltage level required across actuator coil when being held in the open position.
2 Dual hold voltage system included in VCM-D1 Driver
3 Actuators wired in parallel. Combined DCR is 12 OHMS
4 (Continuous/Burst) Continuous frequency rating specified at shutter’s minimum exposure pulse. Burst frequency rating specified for four (4) seconds maximum with one (1) minute minimum between bursts.

 

Electronic Synchronization System


The electronic synchronization system provides a feedback signal (through the driver utilized) after the shutter transfers to the open state. The system incorporates an infrared emitting diode, an infrared sensitive detecting transistor, and an interrupting vane. The vane is attached to the shutter so as to block the light path between the emitter and detector in the closed position. When the shutter transfers to the 80% open position, the vane is removed from the infrared light path, allowing the emitter to switch the detector to the active state. For the CS90, this system uses a similar activation flag attached to the mechanism, which triggers a reflective emitter/detector device. No connection to the designated synchronization pins when no electronic sync. is selected.

vs-cs-ls-sync-schematic-web

Shutter Timing


timing-diagram-white


The question regarding enhancement of shutter speed with the application of user supplied lubricants has been repeatedly asked. It is our experience that lubricating the shutter blades will actually slow the shutter down and eventually render the shutter inoperable. Under no circumstances should any type of lubricant be applied to the shutter blade area.

 

CS90 (w/ VCM-D1 and Teflon® coated blades) Time (msec.)
0-A:     Delay time on opening after current is applied 18.0
A-C: Transfer time on opening 48.0
0-C: Total opening time 66.0
C-E: Min. dwell time with min. input pulse 11.0
B-F: Min. equivalent exp. time 54.0
E-G: Transfer time on closing 57.0
A-G: Total window time 116.0
MET: Min. exposure time 70.0
TEP: Typical exposure pulse >100.0

 

Technical Drawings


Housed

Uniblitz CS90 90mm Optical Shutter Drawing (Housed)

Un-housed

Uniblitz CS90 90mm Optical Shutter Drawing (Unhoused)

Connector Layout

Uniblitz CS90 90mm Optical Shutter Drawing (Connector Layout)