[email protected]
tel. 042-825-7983
fax. 042-825-7984

LS6 6mm Laser Shutter

LS6 6mm Laser Shutter

Part Number: LS6S2T0

Option 

-Driver Compatibility

-Blade Option

-Electronic Sync.

-For use in Vacuum

-Mount

Key Features

-6mm aperture

-Uni-stable operation

-Laser Energy Rating: 5 W/mm2 (with “ZM” blades)

-RoHS Compliant

-Transfer time on opening: 0.7 milliseconds

-Total opening time: 1.7 milliseconds

-Configured for the VCM-D1 Shutter Driver

 

문의하기

→ 상품 상세 정보 : LS6 6mm Laser Shutter

Overview


The Uniblitz LS6 is a high-performance laser shutter, ideal for precision exposure control, laser switching, and other applications that benefit from the precise, repeatable characteristics of the LS shutter series. These include low level laser chopping, and pulse gating, selection, and modulation to 150Hz.

Uni-stable shutter devices, like the LS6, require power to hold the blades in the open state (though the device can be custom-configured for “normally open” operation).

Specifications


For additional technical information please see the LS6 Laser Shutter Datasheet.


Coil Resistance Pulse Voltage to Open Hold Voltage1(Nominal)
48 OHMS +65 VDC +10 VDC

 

Weight Housed Operating Temp. Max. Opening Bounce Max. Closing Bounce Max. Freq. of Operation2 Number of Shutter Blades
7.41 oz (0.21 kg) 0 – 80 °C 15% 5% 20 Hz / 150 Hz 2

 

1 Voltage level required across actuator coil when being held in the open position.
2 (Continuous/Burst) Continuous frequency rating specified at shutter’s minimum exposure pulse. Burst frequency rating specified for four (4) seconds maximum with one (1) minute minimum between bursts.

 

Electronic Synchronization System


The electronic synchronization system provides a feedback signal (through the driver utilized) after the shutter transfers to the open state. The system incorporates an infrared emitting diode, an infrared sensitive detecting transistor, and an interrupting vane. The vane is attached to the shutter so as to block the light path between the emitter and detector in the closed position. When the shutter transfers to the 80% open position, the vane is removed from the infrared light path, allowing the emitter to switch the detector to the active state. For the LS6, this system uses a similar activation flag attached to the mechanism, which triggers a reflective emitter/detector device. No connection to the designated synchronization pins when no electronic sync. is selected.

vs-cs-ls-sync-schematic-web

 

Shutter Timing


timing-diagram-white


The question regarding enhancement of shutter speed with the application of user supplied lubricants has been repeatedly asked. It is our experience that lubricating the shutter blades will actually slow the shutter down and eventually render the shutter inoperable. Under no circumstances should any type of lubricant be applied to the shutter blade area.

 

LS6 (w/ VCM-D1 driver and Teflon® coated blades) Time (msec.)
0-A:     Delay time on opening after current is applied 1.0
A-C: Transfer time on opening 0.7
0-C: Total opening time 1.7
C-E: Min. dwell time with min. input pulse 0.8
B-F: Min. equivalent exp. time 1.5
E-G: Transfer time on closing 0.8
A-G: Total window time 2.3
MET: Min. exposure time 2.0
TEP: Typical exposure pulse >2.5

 

Technical Drawings


Housed

Uniblitz LS6 Technical Drawing (Housed)

Un-housed (Available by Special Order)

Uniblitz LS6 Technical Drawing (Un-housed)

Connector Layout

Uniblitz LS6 Technical Drawing (Connector layout)

Go to Top