[email protected]
tel. 042-825-7983
fax. 042-825-7984

ES6B 6mm Laser Shutter

ES6B 6mm Laser Shutter

Part Number: ES6B1T0

Guaranteed Lifetime: 25,000,000 Cycles


Option 

-Blade Option

-Connector

Key Features

-6mm aperture

-Extremely low-profile form-factor

-Guaranteed lifetime of 25,000,000 actuations

-Bi-stable operation

-RoHS Compliant

-Transfer time on opening: 1.9 milliseconds

-Total opening time: 3.7 milliseconds

-Configured for the VED24 Shutter Driver

 

문의하기

→ 상품 상세 정보 : ES6B 6mm Laser Shutter

Overview


The Uniblitz ES6B is a 6mm bi-stable laser shutter with a very low-profile construction and guaranteed lifetime of 25,000,000 actuations. Its lack of an external protruding actuator makes it very slim and flexible for system integration. Precision exposure control and laser switching are applications that benefit greatly from the precise, highly repeatable characteristics of the ES shutter series.

Bi-stable shutter devices, like the ES6B, require no power to hold the blades in either the open or closed state.

Specifications


For additional technical information please see the ES6B Laser Shutter Datasheet.


Coil Resistance Pulse Voltage to Open Hold Voltage
8 OHMS +10.7 VDC 1 N/A

 

Weight Operating Temp. Max. Opening Bounce Max. Closing Bounce Max. Freq. of Operation 2 Number of Shutter Blades
0.32 oz (9.20 g) -10 – +65 °C 5% 5% 15.0 Hz / 45.0 Hz 1

 

1 Peak voltage as provided by the VED24 Driver
2 (Continuous/Burst) Continuous frequency rating specified at shutter’s minimum exposure pulse. Burst frequency rating specified for four (4) seconds maximum with one (1) minute minimum between bursts.

 

Shutter Timing


timing-diagram-white


The question regarding enhancement of shutter speed with the application of user supplied lubricants has been repeatedly asked. It is our experience that lubricating the shutter blades will actually slow the shutter down and eventually render the shutter inoperable. Under no circumstances should any type of lubricant be applied to the shutter blade area.

 

ES6B (w/ Uniblitz driver and Teflon® coated blades) Time (msec.)
O – A:     Delay time on opening after current applied 1.8
A – C: Transfer time on opening 1.9
O – C: Total opening time 3.7
C – E: Min. dwell time with min. input pulse 9.4
B – F: Min. equivalent exp. time 11.0
D – E: Delay time on closing after current applied 1.8
E – G: Transfer time on closing 1.9
A – G: Total window time 13.2
MET: Min. exposure time 11.0
TEP: Typical exposure pulse >11.0

 

Technical Drawing


Uniblitz ES6B 6mm Laser Shutter Drawing