title: "DSS35B 35mm Optical Shutter"
url: "https://bmlaser.co.kr/dss35b-35mm-optical-shutter/"
description: "DSS35B 35mm Optical ShutterPartNumber: DSS35B1T1Option-BladeOptionKeyFeatures-35mmaperture-Bi-stableoperation-5M1Pand5M1SMadaptersincluded-Extremelyslim, low-profileform-factor-RoHSCompliant-Transfertimeonopening: 23."
image: "https://bmlaser.co.kr/wp-content/uploads/2021/04/895_shop1_15289667509017.jpg"
type: "Article"
datePublished: "2021-04-13T14:37:35+00:00"
dateModified: "2021-04-16T01:10:08+00:00"
---

# DSS35B 35mm Optical Shutter

## 핵심 요지

이 글은 DSS35B 35mm Optical Shutter에 대해 설명합니다. It is guaranteed to operate for 5,000,000 operations Opening Bounce Max

# DSS35B 35mm Optical Shutter

- [DSS35B 35mm Optical Shutter](https://bmlaser.co.kr/images-c/201806/895_shop1_15289667509017.jpg)-[ 문의하기](https://bmlaser.co.kr/contact-us-2/)-[DSS35BOpticalShutterDatasheet.](https://www.uniblitz.com/wp-content/uploads/2016/07/uniblitz-dss35b-datasheet.pdf)Burstfrequencyratingspecifiedforfour(4)secondsmaximumwithone(1)minuteminimumbetweenbursts.##ElectronicSynchronizationSystemThesynchronizationsystemfortheDSS35BincorporatesasmallmagnetmountedtothedrivingmechanismandaHalleffectsensor.Whenthedeviceachievesapproximately80%offullopen,themagnetcausestheHalleffectsensortochangestate,producingasignaltoindicatethattheshutterhasswitchedtotheactivestate.ShowntotheleftistheDSS35B’s shutter schematic which incorporates this electronic synchronization system.

![Uniblitz DSS35B Electronic Sync Schematic Diagram](https://www.uniblitz.com/wp-content/uploads/2016/08/dss35b-sync-schematic-web.png) 링크: https://www.uniblitz.com/wp-content/uploads/2016/08/dss35b-sync-schematic-web.png##ShutterTiming![timing-diagram-white](https://www.uniblitz.com/wp-content/uploads/2016/04/timing-diagram-white.png) 링크: https://www.uniblitz.com/wp-content/uploads/2016/04/timing-diagram-white.pngThequestionregardingenhancementofshutterspeedwiththeapplicationofusersuppliedlubricantshasbeenrepeatedlyasked.Itisourexperiencethatlubricatingtheshutterbladeswillactuallyslowtheshutterdownandeventuallyrendertheshutterinoperable.Undernocircumstancesshouldanytypeoflubricantbeappliedtotheshutterbladearea.| DSS35B (w/ VED24 and Teflon® coated blades) | Time (msec.) | |---|---| | O – A: | Delay time on opening after current applied | 19.

0 | | A – C: | Transfer time on opening | 23. 0 | | O – C: | Total opening time | 42. 0 | | C – E: | Min. dwell time with min. input pulse | 23. 5 | | B – F: | Min. equivalent exp. time | 45. 0 | | D – E: | Delay time on closing after current applied | 18. 0 | | E – G: | Transfer time on closing | 20. 0 | | A – G: | Total window time | 66. 0 | | MET: | Min. exposure time | 45.

0 | | TEP: | Typical exposure pulse | >45. 0 |