---
title: "NS65B 65mm Optical Shutter"
url: "https://bmlaser.co.kr/ns65b-65mm-optical-shutter/"
description: "NS65B 65mm Optical ShutterPartNumber: NS65B1T0-VEDOption-DriverCompatibility-BladeOption-ElectronicSync.-ForuseinVacuum-FlyingLeadsKeyFeatures-65mmaperture-Bi-stableoperation-Onlytwouniquemovingparts-Slim, low-profilefor"
image: "https://bmlaser.co.kr/wp-content/uploads/2021/04/903_shop1_1528968106009.png"
type: "Article"
datePublished: "2021-04-13T14:37:35+00:00"
dateModified: "2021-04-16T01:10:09+00:00"
---

# NS65B 65mm Optical Shutter

## 핵심 요지

이 글은 NS65B 65mm Optical Shutter에 대해 설명합니다. Opening Bounce Max Closing Bounce Max

# NS65B 65mm Optical Shutter

- [NS65B 65mm Optical Shutter](https://bmlaser.co.kr/images-c/201806/903_shop1_1528968106009.png)-[ 문의하기](https://bmlaser.co.kr/contact-us-2/)##SpecificationsForadditionaltechnicalinformationpleaseseethe[NS65BOpticalShutterDatasheet.](https://www.uniblitz.com/wp-content/uploads/2017/03/uniblitz-ns65b-datasheet.pdf)| Coil Resistance | Pulse Voltage to Open | Hold Voltage | |---|---|---| | 12 OHMS 1 | +36 VDC 2 | N/A | | Weight | Operating Temp. | Max. Opening Bounce | Max. Closing Bounce | Max. Freq.

of Operation 3 | Number of Shutter Blades | |---|---|---|---|---|---| | 4. 94 oz (0. 14 kg) | 10 – 50 °C | 15% | 5% | 1. 0 Hz / 3. 0 Hz | 6 | Two 24 OHM coils wired in parallel 2 Peak voltage as provided by the VED24 Driver 3 (Continuous/Burst) Continuous frequency rating specified at shutter’s minimum exposure pulse.

Burst frequency rating specified for four (4) seconds maximum with one (1) minute minimum between bursts.

## Electronic Synchronization System This sync schematic illustrates the wiring for the NS65B. The schematic also shows the two 24 Ω coils wired in parallel to provide an equivalent resistance of 12 Ω. Presently, the NS65B does not include a synchronization system as a standard option.

Pins 3, 4, and 5 have no connections at this time. The synchronization feature may be available by special order if it is required for your application. Please [contact us](https://www.uniblitz.com/contact-us/)todiscussyourrequestinfurtherdetail.![UniblitzNS65BSchematic](https://www.uniblitz.com/wp-content/uploads/2016/08/ns65b-sync-schematic-web.png) 링크: https://www.uniblitz.com/wp-content/uploads/2016/08/ns65b-sync-schematic-web.png##ShutterTiming![timing-diagram-white](https://www.uniblitz.com/wp-content/uploads/2016/04/timing-diagram-white.png) 링크: https://www.uniblitz.com/wp-content/uploads/2016/04/timing-diagram-white.pngThequestionregardingenhancementofshutterspeedwiththeapplicationofusersuppliedlubricantshasbeenrepeatedlyasked.Itisourexperiencethatlubricatingtheshutterbladeswillactuallyslowtheshutterdownandeventuallyrendertheshutterinoperable.Undernocircumstancesshouldanytypeoflubricantbeappliedtotheshutterbladearea.| NS65B (w/ VDM1000 and Teflon® coated blades) | Time (msec.) | |---|---| | O – A: | Delay time on opening after current applied | 10.

0 | | A – C: | Transfer time on opening | 33. 0 | | O – C: | Total opening time | 43. 0 | | C – E: | Min. dwell time with min. input pulse | 15. 0 | | B – F: | Min. equivalent exp. time | 47. 0 | | D – E: | Delay time on closing after current applied | 12. 0 | | E – G: | Transfer time on closing | 31. 0 | | A – G: | Total window time | 79. 0 | | MET: | Min. exposure time | 70.

0 | | TEP: | Typical exposure pulse | >70. 0 |
